Todd Water Control Unit 2100 — DST 218
The Todd Water Control Unit 2100 is an economical solution for the efficient management of water service during the embalming process. The WCU 2100 comes complete with hydro-aspirator, hot and cold water embalming machine fill, and hot and cold water for the morgue table. Wall mounted.
A Duncan Stuart Todd Design
Stock Status: In Stock Ships in 1 to 2 business days
Description
Features
Efficient
Hydro-aspirates and provides hot and cold water to the embalming machine and table.
Includes integral back flush, two 12″ clear hoses and quick-disconnects.
Reduces Toxins
Aspirator waste is plumbed directly into the waste line minimizing airborne exposure.
Versatile
For new construction or major renovation.
Space-saving footprint, 16″ x 1 3/8″.
Mounts on wall.
Frees up counter and under-counter space.
Technical Information
Size
16″ x 1 3/8″
Weight
15 lbs
Construction
Stainless steel housing and chrome fittings
Aspiration
29# @ 65 psi
Components
12′ clear hose
3 quick disconnects
12′ Clear Tubing
3 quick disconnects
12′ Clear Tubing
Riser Height
Standard is 21.75″ from counter top
15.75″ and 26.75″ available
15.75″ and 26.75″ available
Compliancy
OSHA compliant when installed per manufacturer’s guidelines
Recommended Accessories
Volume Pressure Kit DST 302
Installation
Assembly
Pre-assembled; pre-plumbed
Mounting
Wall mounted
Supplied with stainless steel mounting hardware
Template and instructions provided
Supplied with stainless steel mounting hardware
Template and instructions provided
Cold Water Lines
one (1) 1″ to angle stop
two (2) flexible connections from angle stop
two (2) flexible connections from angle stop
Hot Water Lines
one (1) 1/2″ to angle stop
one (1) 1/2″ flexible connection from angle stop
one (1) 1/2″ flexible connection from angle stop
Auxiliary Requirements for Proper Aspiration Operation
1″ cold water line to the preparation room
Continuously operating water pressure of 65 to 85 psi
We recommend units be installed with a volume pressure control system DST 302
Continuously operating water pressure of 65 to 85 psi
We recommend units be installed with a volume pressure control system DST 302
Auxiliary Requirements for Code Compliancy
Reduced pressure backflow preventers required on cold and hot water lines
Mark piping to Todd WCU 2100 non-potable per plumbing code requirements
Mark piping to Todd WCU 2100 non-potable per plumbing code requirements
NOTE
Clean out all plumbing lines prior to start up
Install in accordance with all applicable codes
Install in accordance with all applicable codes